Specification

Measurement Simulation
Chip operating voltage 1.0 V 1.0 V
Chip operating current 30 uA 50 uA
Ultrasonic transmitter input voltage 5.0V p-p 40K Hz Sine -
Maximum Distance measurement 2.0 Meters in Lab -
Minimum Distance measurement 16.5 cm 10 cm
Measurement error <5% -
Adjusted input DC bias voltage 510 mV 500 mV
Adjusted Mixer Reference voltage 647 mV 650 mV
Adjusted Comparator Reference Voltage 707 mV 670 mV